JGW-T1910142-v2

DocDB Home ]  [ Search ] [ Recent Changes ]

Noise and range calculations for using High Power Coil Driver for the test mass stage of cryopayload

Document #:
JGW-T1910142-v2
Document type:
T
Submitted by:
Yuta Michimura
Updated by:
Yuta Michimura
Document Created:
23 Apr 2019, 22:58
Contents Revised:
24 Apr 2019, 18:25
Metadata Revised:
24 Apr 2019, 18:25
Viewable by:
Modifiable by:

Quick Links:
Latest Version

Other Versions:
JGW-T1910142-v1
23 Apr 2019, 23:04
JGW-T1910142-v0
23 Apr 2019, 22:58
Abstract:
Noise and range calculations for using High Power Coil Driver for the test mass stage of cryopayload.

High Power Coil Driver for one of the ETMs gives noise within the range of O3 goal.

https://granite.phys.s.u-tokyo.ac.jp/svn/LCGT/trunk/kagranoisebudget/Suspensions
http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/VIS/ActuatorDesign