JGW-T1605335-v0

DocDB Home ]  [ Search ] [ Recent Changes ]

Position measurement of the iKAGRA BS mirror and vacuum chamber

Document #:
JGW-T1605335-v0
Document type:
T
Submitted by:
Naoko Ohishi
Updated by:
Naoko Ohishi
Document Created:
28 Jun 2016, 17:18
Contents Revised:
28 Jun 2016, 17:18
DB Info Revised:
28 Jun 2016, 17:18
Viewable by:
Modifiable by:
Other Versions:
JGW-T1605335-v6
19 Jul 2016, 16:53
JGW-T1605335-v5
19 Jul 2016, 16:49
JGW-T1605335-v4
19 Jul 2016, 15:54
JGW-T1605335-v3
28 Jun 2016, 17:22
JGW-T1605335-v2
28 Jun 2016, 17:19
JGW-T1605335-v1
28 Jun 2016, 17:19
Abstract:
We have measured position of iKAGRA BS mirror and BS chamber on 7, 8th June 2016 by using 3D measurement system. The result are as follows; the mirror was set -1.6mm, -6.2mm, -6.6mm from the planned position inside the vacuum chamber. We also found that the BS chamber was located about +10mm different place in y direction from the planned position if we rely on the position of the floor reference points.
Files in Document:
None
Authors:
DocDB Home ]  [ Search ] [ Recent Changes ]

DocDB Version 8.7.10, contact Document Database Administrators