loss freq(1/yr) (A) Maintenance - long 60 0.5 - medium 5 1 - short (adjustment) 0.5 12 ------------------------------------ subtotal 41.0 days (B) Malfunctions - laser exchange 4 0.2 - DGS system error 4 0.5 - AEL malfunction 4 1.0 - FCL accident 4 1.0 - suspension break 50 0.2 - DAS PC exchange 1 0.5 - local sensor error 1 0.5 ------------------------------------ subtotal 21.8 days ------------------------------------ total 62.8 days (=17.2%) 長期メンテナンスの内訳は以下です: 昇温(15d)+真空リーク(0.1d)+作業(10d)+真空(4.9d)+冷却(30d)=60d 干渉計休止時間の内訳は以下の通りです(頻度×ロス)。 IFO unlock 1/day 20 min laser down 1/year 1 hour MC unlock 2/year 30 min OMC adjust 2/year 30 min big earthquake 1/week 2 hour others 1/week 2 hour ------------------------------------ total 0.91 hours/day (=3.80%) (1-0.172)x(1-0.0380)=0.7964